Winner901 Photon Correlation (DLS) Nanoparticle Size & Zeta Potential Analyzer

High-Precision Particle Size Distribution & Characterization System (Winner901 DLS Nano Partikül Boyutu ve Zeta Potansiyeli Analizörü)

The Winner901 Photon Correlation (DLS) Nanoparticle Size & Zeta Potential Analyzer is an advanced particle characterization instrument engineered for accurate and repeatable determination of particle size distribution (D10, D50, D90, D[4,3], D[3,2]) across pharmaceutical, chemical, mining, battery material, ceramic, coating, food, and nanotechnology laboratories. Fully compliant with ISO 13320 / ISO 13322 international standards, it combines automatic optical alignment with one-click SOP testing for seamless QC and R&D workflows.

Key Features

  • Measurement Range: Particle Size: 0.3 – 10,000 nm (0.3 nm – 10 µm) | Zeta Potential: -500 mV to +500 mV
  • Measurement Principle & Optics: Dynamic Light Scattering (DLS / Photon Correlation Spectroscopy) & Electrophoretic Light Scattering (ELS)
  • Accuracy & Detector Performance: Accuracy & Repeatability: ≤ 1.0% (CRM Dav) | Electrophoretic Mobility: > ±20 µm·cm/V·s | Max Conductivity: 200 mS/cm
  • Dispersion & Sample Handling: 5–90°C (±0.1°C) Precision Temperature Control, 0.1–100 mg/mL Concentration Range, 1–4 mL Sample Cell Volume
  • Intelligent Software & Reporting: One-click SOP automated operation, Free/R-R/Log-Normal distribution models, multi-batch statistical comparison, and Word/Excel/PDF export
Technical Specifications
Parameter / Component Specification
Model Winner901 DLS Nano Partikül Boyutu ve Zeta Potansiyeli Analizörü
Measurement Range Particle Size: 0.3 – 10,000 nm (0.3 nm – 10 µm) | Zeta Potential: -500 mV to +500 mV
Measurement Principle & Optics Dynamic Light Scattering (DLS / Photon Correlation Spectroscopy) & Electrophoretic Light Scattering (ELS)
Accuracy & Repeatability Accuracy & Repeatability: ≤ 1.0% (CRM Dav) | Electrophoretic Mobility: > ±20 µm·cm/V·s | Max Conductivity: 200 mS/cm
Dispersion & Sampling System 5–90°C (±0.1°C) Precision Temperature Control, 0.1–100 mg/mL Concentration Range, 1–4 mL Sample Cell Volume
Operation Mode & Software One-Click SOP Automated Testing | Custom D1–D100 Percentiles, Differential & Cumulative Distribution Curves
Dimensions, Weight & Structure 600 × 420 × 210 mm, 28 kg | Tek Tuşla SOP Otomatik Nano Boyut & Zeta Potansiyeli Ölçümü
Application Areas
  • Pharmaceutical APIs, excipients, emulsions, suspensions, nasal sprays, and medical nebulizer/inhaler aerosols
  • Chemicals, paints, powder coatings, inks, polymers, cosmetics, food ingredients, coffee, and agrochemicals
  • Minerals, cement, ceramics, lithium-ion battery cathode/anode powders, metal powders, abrasives, and catalysts
  • Nanotechnology, colloidal dispersions, liposomes, exosomes, and surface charge (Zeta potential) stability studies